    簡要描述:Bante900/901/902/903多參數(shù)水質(zhì)測量儀儀器功能:
    ● Bante900: pH, ORP, 離子, 電導(dǎo)率, TDS, 鹽度, 電阻率, 溶解氧
    ● Bante901: pH, ORP, 離子, 電導(dǎo)率, TDS, 鹽度, 電阻率
    ● Bante902: pH, ORP, 溶解氧
    ● Bante903: 電導(dǎo)率, TDS, 鹽度, 電阻率, 溶解氧

    產(chǎn)品型號: Bante900/901/902/903

    所屬分類:水質(zhì)監(jiān)測儀

    更新時間:2024-08-15

    詳細(xì)說明:

    Bante90系列多參數(shù)水質(zhì)測量儀包含四款型號, 產(chǎn)品適用于測 
    量液體的pH, 氧化還原電位(ORP),  離子濃度, 電導(dǎo)率, 溶解性 
    總固體( TDS ), 鹽度, 電阻率, 溶解氧( DO )等水質(zhì)參數(shù)。. 
      
    Bante900/901/902/903多參數(shù)水質(zhì)測量儀儀器功能: 
    ● Bante900: pH, ORP, 離子, 電導(dǎo)率, TDS, 鹽度, 電阻率, 溶解氧 
    ● Bante901: pH, ORP, 離子, 電導(dǎo)率, TDS, 鹽度, 電阻率 
    ● Bante902: pH, ORP, 溶解氧 
    ● Bante903: 電導(dǎo)率, TDS, 鹽度, 電阻率, 溶解氧 
      
    Bante900/901/902/903多參數(shù)水質(zhì)測量儀自動校準(zhǔn): 
    儀器具有多點按鍵校準(zhǔn)功能, 校準(zhǔn)時儀器自動提示您需要使 
    用的校準(zhǔn)液類型, 您只需按提示將電極傳感器浸入相應(yīng)的校 
    準(zhǔn)液中, 按ENTER鍵, 儀器即會自動校準(zhǔn)。 
      
    自動識別標(biāo)準(zhǔn)緩沖液: 
    校準(zhǔn)時, 如果您錯誤使用標(biāo)準(zhǔn)緩沖液或者使用嚴(yán)重變質(zhì)的校 
    準(zhǔn)液, Bante90系列將自動報警并提示ERROR。 
      
    多模式離子測量: 
    Bante 900內(nèi)置多種離子測量模式, 按ENTER鍵, 儀器依次轉(zhuǎn)換 
    離子濃度測量模式(pX, mg/L, ppm)。 

    相對mV測量功能: 
    在ORP 測量模式, 儀器具有相對mV測量功能,  使用氧化還原 
    電位校準(zhǔn)液, 您可以修正測量誤差以提升ORP 測量精度。. 
      
    自動量程轉(zhuǎn)換: 
    測量電導(dǎo)率或TDS 時, 儀器具有自動量程轉(zhuǎn)換功能。當(dāng)電極 
    傳感器浸入樣品后,  Bante 90系列將自動掃描當(dāng)前測量值并 
    轉(zhuǎn)換量程,  儀器將以精確的分辯率顯示終點測量值。.


     Model

                               Bante900

    Bante901

    Bante902

    Bante903

       pH測量范圍

    -2.000~16.000pH

       pH測量精度

    ±0.002pH

       pH校準(zhǔn)點

    2點

       使用校準(zhǔn)液

    pH4.00/6.86/9.18 或 pH4.01/7.00/10.01

       溫度補償范圍

    0~100oC

       ORP測量范圍

    -1999.9~1999.9mV

       ORP測量精度

    ±0.2mV

       離子濃度測量范圍

    0~19999ppm (基于離子電極量程)

    ---

    ---

       離子濃度測量精度

    ±0.5% F.S (一介離子), ±1% F.S (二介離子)

    ---

    ---

       離子校準(zhǔn)點

    2~5點

    ---

    ---

       使用校準(zhǔn)液

    10-2, 10-3, 10-4, 10-5, 10-6mol/L

    ---

    ---

       溫度補償范圍

    0~100oC

    ---

    ---

       電導(dǎo)率測量范圍

    0~200mS/cm

    ---

       電導(dǎo)率測量精度

    ±0.5% F.S

    ---

       電導(dǎo)率校準(zhǔn)點

    1點

    ---

       可選電極常數(shù)

    K=0.1, 1, 10

    ---

       溫度補償系數(shù)

    0~3.9%每oC

    ---

       溫度補償范圍

    0~50oC

    ---

       TDS測量范圍

    0~Max.200ppt

    ---

       TDS測量精度

    ±1% F.S

    ---

       TDS轉(zhuǎn)換系數(shù)

    0.01~1.00, 默認(rèn)值0.67

    ---

       鹽度測量范圍

    0.00~50.0ppt

    ---

       鹽度測量精度

    ±1% F.S

    ---

       電阻率測量范圍

    0~100MΩ

    ---

       電阻率測量精度

    ±1% F.S

    ---

       溶解氧測量范圍

    0.00~20.00mg/L (ppm)

    ---

       溶解氧測量精度

    ±0.3mg/L

    ---

       % 飽和度量程

    0~200.0%

    ---

       % 飽和度精度

    ±5.00%

    ---

       校準(zhǔn)點

    1或2點

    ---

       鹽度補償范圍

    0~35g/L

    ---

       大氣壓力設(shè)定

    450~850mmHg, 60.0~112.5kPa

    ---

       溫度補償范圍

    0~40oC

    ---

       溫度測量范圍

    0~100oC, 32~212oF

       溫度測量精度

    ±0.3oC, ±0.5oF

       儲存數(shù)據(jù)

    99組

       通訊輸出

    USB標(biāo)準(zhǔn)

       電源類型

    9V/350mA電源適配器

       外形尺寸

    210(L)×188(W)×60(H)mm

       儀器重量

    1.7kg